TAWG CARD

Tested in Targeted Switches for Superior Performance
Quality Assurance
Risk Free Return Policy
30 Days Easy Returns
Guarantee Compatibility and Reliability
Category:

Description

  • Parameter

    Min

    Typ

    Max

    Unit

    Number of Channels

    40/48

    Channel Spacing

    100

    GHz

    Cha. Center Wavelength

    C -band

    nm

    Center Frequency Accuracy

    ±0.05

    nm

    1dB Passband

    0.4

    nm

    3dB Passband

    0.6

    nm

    Insertion Loss Passband

    4.5

    6.0

    dB

    Adjacent Channel Isolation

    25

    dB

    Non-Adjacent,Channel Isolation

    35

    dB

    Total Crosstalk

    25

    Insertion Loss Uniformity

    1.5

    dB

    Directivity(Mux Only)

    40

    dB

    Insertion Loss Ripple

    0.5

    dB

    Optical Return loss

    40

    dB

    Polarization Dependent Loss(PDL)

    0.3

    0.5

    dB

    Polarization Mode Dispersion(PMD)

    0.5

    ps

    Maximum Optical Power

    24

    dBm

    Operating Temperature

    -5℃~+75℃

    Storage Temperature

    -40℃~85℃

    Relative humidity

    5 to 95% maximum, non-condensing

    Power Consumption

    ≤25W

    Size

    AWG Module

    53(W)× 195(H)× 252(D)

    8-slot chassis

    482.6(W)x360(D)x109(H)

    16-slot chassis

    482.6(W)x360(D)x261.6(H)

  • This component is designed for use within the C -band release of DWDM system.

    AWG device uses thermal-type thermal arrayed waveguide grating module with a unique package design is based on a silicon substrate planar waveguide optical path (PLC) grating technology, the key modules, reduce power consumption, the Ad Hoc Working Group kit, use reliable thermal plastic , low thermal conductivity and precise working temperature control, accurate channel coupling, low insertion loss, high channel isolation and high stability.

    • Channel spacing 100GHZ (0.8 nm) up to 48 channels can be multiplexed
    • High integration
    • Low insertion loss, insertion loss ≤5dB, typ 4.5dB
    • High channel isolation, adjacent isolation ≥25dB; non-adjacent isolation ≥35dB
    • Advanced network management features: support SNMP, CLI, Web, management approach, Full graphical management

    ST8000 chassis compatibility:

    • Fit STC8000-CH08 8-slot powered chassis
    • Fit STC8000-CH16 16-slot powered chassis
Quality Certifications